2.9.18. Import day-specific and hour-specific data

Another function of Smkinven that only applies to point sources is importing day- and hour-specific data. It can read three input ASCII formats:

In addition to reading the files, Smkinven ensures that the records listed in day- and hour-specific files match records provided in the annual inventory inputs. This is necessary because SMOKE builds its list of all point sources based on the annual and/or average-day inventory files, and these are the only sources that will be listed in the SMOKE intermediate inventory file. Smkinven requires that the year associated with the date of the day-specific and hour-specific emissions is the same as the base year. Smkinven generates an error message when it cannot match a day- or hour-specific source with an inventory source. Please refer to Section 6.13, “Smkinven for more information about how Smkinven can be used to import these data.

Smkinven also can process the hourly CEM data in a more sophisticated way. Hourly heat input from the CEM data are used to allocate annual emissons to hourly emission data. First of all, the utility program CEMScan must be run before Smkinven, see more information at (Section 5.3.4, “CEMScan).